| Name |
Format |
Description |
Link |
|
33 |
Covers: objective of test, TDR Measurements, and discusses result plots |
https://gdr.openei.org/files/1172/Field_notes%20_Cymric.pdf |
|
33 |
Data plot of 450 kHz, 2500 kHz, 4500 kHz measurements showing amplitude versus time (us) |
https://gdr.openei.org/files/1172/compare_plot_new.pdf |
|
8 |
TDR response of 450 kHz were made on the final morning in well TO15-5, using TO15-6 as a return electrode. The input voltage was set as 70V. We can set a TDR return at 1.8 – 2 µs, which is the reflection at about 738—862 ft deep. The shape of the TDR return indicates this is an open termination. Based on our knowledge of the well structure, this return is from the end of the production string. |
https://gdr.openei.org/files/1172/TDR_20190221094108.csv |
|
8 |
TDR response of 2500 kHz were made on the final morning in well TO15-5, using TO15-6 as a return electrode. The input voltage was set as 70V. We can set a TDR return at 1.8 – 2 µs, which is the reflection at about 738—862 ft deep. The shape of the TDR return indicates this is an open termination. Based on our knowledge of the well structure, this return is from the end of the production string. |
https://gdr.openei.org/files/1172/TDR_20190221094127.csv |
|
8 |
TDR response of 4500 kHz were made on the final morning in well TO15-5, using TO15-6 as a return electrode. The input voltage was set as 70V. We can set a TDR return at 1.8 – 2 µs, which is the reflection at about 738—862 ft deep. The shape of the TDR return indicates this is an open termination. Based on our knowledge of the well structure, this return is from the end of the production string. |
https://gdr.openei.org/files/1172/TDR_20190221093903.csv |