75 |
Velocity step test on 30 degree saw-cut Westerly Granite at room temperature. Data: Pump A is upstream fluid, Pump B is confining fluid, Pump C is axial fluid. P is pump pressure, V is remaining volume in pump, Q is fluid flow rate from pump. d_axial and d_shear are axial and shear displacement, SigmaN is normal stress, Pf is fluid pressure, tau is shear stress (all in MPa), mu is friction coefficient. vera_timeshift, vera_amp and vera_RMS are the non-linear acoustic data, timeshift (microseconds), amplitude and RMS amplitude respectively. |
https://gdr.openei.org/files/1400/comb_data_Test07.mat |
|
75 |
Pressure stepping test on 30 degrees saw-cut Westerly Granite bare surface, roughened with Utah FORGE granitoid powder. Data: Pump A is upstream fluid, Pump B is confining fluid, Pump C is axial fluid. Downstream fluid pressure is open to atmosphere. P is pump pressure, V is remaining volume in pump, Q is fluid flow rate from pump. d_axial and d_shear are axial and shear displacement, SigmaN is normal stress, Pf is fluid pressure, tau is shear stress (all in MPa), mu is friction coefficient. vera_timeshift, vera_amp and vera_RMS are the non-linear acoustic data, timeshift (microseconds), amplitude and RMS amplitude respectively. |
https://gdr.openei.org/files/1400/comb_data_Test12.mat |