| Name |
Format |
Description |
Link |
|
8 |
Experimental data for fluid injection test at room temperature. Confining pressure and shear stress are held constant. Axial pressure is set so the shear force is 80% of the shear strength. Pore pressure is designed to increase step by step, 0.3MPa/3mins. See "0README.txt" for descriptions of the data columns in this file. |
https://gdr.openei.org/files/1628/jp-roomT-0.8.csv |
|
8 |
Experimental data for fluid injection test at room temperature. Confining pressure and shear stress are held constant. Axial pressure is set so the shear force is 80% of the shear strength. Pore pressure is designed to increase step by step, 0.3MPa/3mins. See "0README.txt" for descriptions of the data columns in this file. |
https://gdr.openei.org/files/1628/jp-roomT-0.8-2.csv |
|
8 |
Experimental data for fluid injection test at room temperature. Confining pressure and shear stress are held constant. Axial pressure is set so the shear force is 60% of the shear strength. Pore pressure is designed to increase step by step, 0.3MPa/3mins. See "0README.txt" for descriptions of the data columns in this file. |
https://gdr.openei.org/files/1628/jp-roomT-0.6.csv |
|
8 |
Experimental data for fluid injection test at room temperature. Confining pressure and shear stress are held constant. Axial pressure is set so the shear force is 80% of the shear strength. Pore pressure is designed to increase step by step, 0.3MPa/3mins. See "0README.txt" for descriptions of the data columns in this file. |
https://gdr.openei.org/files/1628/jp-roomT-0.8-4.csv |
|
8 |
This file contains normal stiffness measurement data at 81 degrees C. See "0REAME.txt" for descriptions of data columns. |
https://gdr.openei.org/files/1628/normal%20stiffness%20data-81%E2%84%83.csv |
|
8 |
This file contains normal stiffness measurement data at room temperature. See "0REAME.txt" for descriptions of data columns. |
https://gdr.openei.org/files/1628/normal%20stiffness%20data-roomT.csv |
|
22 |
Schematic diagram of the experimental apparatus. |
https://gdr.openei.org/files/1628/apparatus%20schematic%20diagram%20%281%29.jpg |
|
8 |
Experimental data for fluid injection test at 141 degrees C. Confining pressure and shear stress are held constant. Axial pressure is set so the shear force is 80% of the shear strength. Pore pressure is designed to increase step by step, 0.3MPa/3mins. See "0README.txt" for descriptions of the data columns in this file. |
https://gdr.openei.org/files/1628/jp-141%E2%84%83-0.8.csv |
|
22 |
Camera photograph of the experimental apparatus. |
https://gdr.openei.org/files/1628/Apparatus%20figure%20%282%29.jpg |
|
8 |
This file contains normal stiffness measurement data at 141 degrees C. See "0REAME.txt" for descriptions of data columns. |
https://gdr.openei.org/files/1628/normal%20stiffness%20data-141%E2%84%83.csv |
|
8 |
Experimental data for fluid injection test at 78 degrees C. Confining pressure and shear stress are held constant. Axial pressure is set so the shear force is 80% of the shear strength. Pore pressure is designed to increase step by step, 0.3MPa/3mins. See "0README.txt" for descriptions of the data columns in this file. |
https://gdr.openei.org/files/1628/jp-78%E2%84%83-0.8.csv |
|
47 |
This file explains each experimental setup and the test conditions for each run, lists each file in this repository and details the relevant experimental conditions for each, and defines the columns in the CSV files. |
https://gdr.openei.org/files/1628/Read%20me%20%282%29.txt |
|
8 |
Experimental data for fluid injection test at 137 degrees C. Confining pressure and shear stress are held constant. Axial pressure is set so the shear force is 80% of the shear strength. Pore pressure is designed to increase step by step, 0.3MPa/3mins. See "0README.txt" for descriptions of the data columns in this file. |
https://gdr.openei.org/files/1628/jp-137%E2%84%83-0.8.csv |
|
8 |
Experimental data for fluid injection test at 81 degrees C. Confining pressure and shear stress are held constant. Axial pressure is set so the shear force is 80% of the shear strength. Pore pressure is designed to increase step by step, 0.3MPa/3mins. See "0README.txt" for descriptions of the data columns in this file. |
https://gdr.openei.org/files/1628/jp-81%E2%84%83-0.8.csv |
|
8 |
Experimental data for fluid injection test at room temperature. Confining pressure and shear stress are held constant. Axial pressure is set so the shear force is 80% of the shear strength. Pore pressure is designed to increase step by step, 0.3MPa/3mins. See "0README.txt" for descriptions of the data columns in this file. |
https://gdr.openei.org/files/1628/jp-roomT-0.8-3.csv |
|
8 |
Experimental data for fluid injection test at room temperature. Confining pressure and shear stress are held constant. Axial pressure is set so the shear force is 70% of the shear strength. Pore pressure is designed to increase step by step, 0.3MPa/3mins. See "0README.txt" for descriptions of the data columns in this file. |