Magnitude and phase of the measured and simulated S-parameters for two CE cells and one CB cell. The CE cells are labeled 'Paired' and 'Direct' to differentiate them and the CB cell is labeled 'CB'. Frequency for both the measured and simulated data has units of GHz from 140 to 230 GHz. The magnitude of the transmission coefficient (S21) for the cells is in units of decibels (dB). The reflection coefficients (S11 and S22) for the cells are in linear units for the magnitude and are in units of degrees for the phase. The measured and simulated Stability factor (K factor) for the cells is also included and does not have units. |
https://data.nist.gov/od/ds/mds2-3403/fig4.txt |
|
0 |
Magnitude and phase of the measured and simulated S-parameters for the 4-finger HBT. Frequency for both the measured and simulated data has units of GHz from 140 to 230 GHz. The transmission coefficients (S21 and S12) for the 4-finger HBT are in units of decibels (dB) for the magnitude and are in units of degrees for the phase. The reflection coefficients (S11 and S22) for the 4-finger HBT are in linear units for the magnitude and are in units of degrees for the phase. There are five measured sites which are indicated in the file by their site number. |
https://data.nist.gov/od/ds/mds2-3403/fig3.txt |
|
0 |
Magnitude and phase of the measured and simulated S-parameters for a via and short-circuit manifold test structure. Frequency for both the measured and simulated data has units of GHz from 140 to 230 GHz. The transmission coefficients (S21 and S12) for the via are in units of decibels (dB) for the magnitude and are in units of degrees for the phase. The reflection coefficients (S11 and S22) for the short-circuit manifold test structure are in linear units for the magnitude and are in units of degrees for the phase. |
https://data.nist.gov/od/ds/mds2-3403/fig1.txt |
|
0 |
Magnitude and phase of the measured and simulated S-parameters for the single HBT. Frequency for both the measured and simulated data has units of GHz from 140 to 230 GHz. The transmission coefficients (S21 and S12) for the single HBT are in units of decibels (dB) for the magnitude and are in units of degrees for the phase. The reflection coefficients (S11 and S22) for the single HBT are in linear units for the magnitude and are in units of degrees for the phase. There are six measured sites which are indicated in the file by their site number. |
https://data.nist.gov/od/ds/mds2-3403/fig2.txt |