Sample Data from a Distributed Acoustic Sensing Experiment at Garner Valley, California

Description

In September 2013, an experiment using Distributed Acoustic Sensing (DAS) was conducted at Garner Valley, a test site of the University of California Santa Barbara (Lancelle et al., 2014). This submission includes one 45 kN shear shaker (called "large shaker" on the basemap) test for three different measurement systems. The shaker swept from a rest, up to 10 Hz, and back down to a rest over 60 seconds. Lancelle, C., N. Lord, H. Wang, D. Fratta, R. Nigbor, A. Chalari, R. Karaulanov, J. Baldwin, and E. Castongia (2014), Directivity and Sensitivity of Fiber-Optic Cable Measuring Ground Motion using a Distributed Acoustic Sensing Array (abstract # NS31C-3935), AGU Fall Meeting.

Resources

Name Format Description Link
8 x,y coordinates of each DAS channel in the fiber-optic cable. https://gdr.openei.org/files/481/DAS_locationcorrected%20%281%29.csv
8 Description of the columns in the "L28 Geophone Data.dat" file for the geophones. https://gdr.openei.org/files/481/Geophone_Header%20%281%29.csv
21 List of filenames of the 1000 samples per second data files. https://gdr.openei.org/submissions/492
21 Includes the abstract for "Directivity and Sensitivity of Fiber-Optic Cable Measuring Ground Motion using a Distributed Acoustic Sensing Array" report that was presented at the 2014 AGU Fall Meeting. https://agu.confex.com/agu/fm14/webprogram/Paper19828.html
8 x,y coordinates of all instruments and active tests, excluding the DAS channels. https://gdr.openei.org/files/481/stationcoordinates%20%282%29.csv
33 Map of the Garner Valley field site including source locations https://gdr.openei.org/files/481/basemap%20%281%29.pdf
8 Accelerometer data for the four sensors along one of the fiber-optic cable lines. Individual columns are described in the file. The sample rate is 1000 samples per second. https://gdr.openei.org/files/481/20130910231335.UCLAGR1%20%281%29.csv
9 L28 Geophone data. The description of the columns is in the “Geophone_Header.csv” file. The sample rate is 1000 samples per second. https://gdr.openei.org/files/481/23%20%281%29.dat
8 Accelerometer data for four sensors on the Mini-Me structure. Individual columns are described in the file. The sample rate is 1000 samples per second. https://gdr.openei.org/files/481/20130910231307.UCLAGR2%20%281%29.csv
0 Each column represents a time series for a different channel in the cable. The fiber starts in the hut, moves out from there to the end of the array, and then doubles back to the hut in the same casing (see basemap.pdf). There is a new channel approximately every meter, the locations of which are denoted in “Corrected DAS Channel Locations.” The sample rate is 200 samples per second. https://gdr.openei.org/files/481/large%20shaker%20NEES_130910161319%20%281%29.sgy

Tags

  • project-summary
  • vibroseis
  • fiber-optic
  • distributed-acoustic-sensing
  • geophone
  • garner-valley
  • porotomo
  • california
  • accelerometer
  • poster
  • map
  • das
  • fiber-optics
  • geothermal

Topics