Rare Earth Element Sorption Study on sieved -50 +100 mesh fraction of Media 1 in Brine 1 with Different Starting pHs at 70C

Description

This is a continuation of the rare earth element sorption study for shaker bath tests on 2g media #1 in 150mL brine #1 with different starting pH's at 70C. In a previous submission we reported data for shaker bath tests for brine #1 with starting pH's of 3.5, 4.5 and 5.5. In this submission we these pH's compared to starting brine #1 pH's of 6, and 7.

Resources

Name Format Description Link
53 This is the raw data set for a shaker bath test with 2g of -50 +100 media #1 in 150mL of brine #1 with a starting pH of 6 and 7 shaking for 90 minutes. The concentration of REE's was 2ppm each of the REE7 metals. (Samples GG2-105_) https://gdr.openei.org/files/636/20150929%20Shaker%20bath%20test%20Brine%201%20pH%206%20and%207%20150mL%202ppm%20each%207%20metal%202g%20KGH%20at%2070C%20%28GG2-105%29.xlsx
33 This pdf is a sorption study that shows the percentages of REE's (-50 100 media 1) removed from solution at different starting brine #1 pH's. In a previous submission we showed the comparison of REE's removed from solution at starting brine #1 pH's of 3.5, 4.5, and 5.5. In this submission we will compare those results with the results of brines with starting pH's of 6 and 7. https://gdr.openei.org/files/636/REE%20Sorption%20Study%20on%20sieved%20mesh%20fractions%20of%20media%201%20in%20brine%201%20with%20Different%20Starting%20pH%27s%20at%2070C.pdf
53 This is the raw data set for a shaker bath test for 2g of +50 +100 mesh media #1 in 150mL brine #1 at 70C shaking for 90 minutes at pH 5.5. The concentration of REE's was 2ppm each for the REE7 metals. (Samples GG2-86_) https://gdr.openei.org/files/636/20150721%20Shaker%20Bath%20test%20Brine%201%202ppm%20each%207%20metal%20150mL%202g%20KGH%20media%20pH5.5%20at%2070C%20GG2-86.xlsx
53 This is the raw data set for a shaker bath test for 2g of +50 +100 mesh media #1 in 150mL of brine #1 at 70C and a starting pH of 4.5 shaking for 90 minutes. Th e concentration of REE's was 2ppm each of the REE7 metals. (Samples GG2-87_) https://gdr.openei.org/files/636/20150721%20Shaker%20Bath%20test%20Brine%201%202ppm%20each%207%20metal%20150mL%202g%20KGH%20media%20pH4.5%20at%2070C%20GG2-87.xlsx
53 This is the raw data set for a shaker bath test for 2g of +50 +100 mesh media #1 in 150mL of brine #1 at 70Cwith a starting pH of 3.5 shaking for 90 minutes. The concentration of REE's was 2ppm each for the REE7 metals. (Samples GG2-88_) https://gdr.openei.org/files/636/20150721%20Shaker%20Bath%20test%20Brine%201%202ppm%20each%207%20metal%20150mL%202g%20KGH%20media%20pH3.5%20at%2070C%20GG2-88.xlsx

Tags

  • rare-earth-elements
  • ree
  • shaker-bath-test
  • shaker-bath-tests
  • elevated-temperature
  • media-1
  • brine-1
  • geothermal-mineral-recovery
  • sorption-study
  • geothermal
  • ph