Quasi-continuous voltage standard using sinusoidal and pulse-driven Josephson junction arrays

Description

Dataset for multiple publishable figures in the paper entitled "Quasi-continuous voltage standard using sinusoidal and pulse-driven Josephson junction arrays" submitted to Meas. Sci. and Tech. journal. Figure 3. (a) Pattern of pulses used to generate a dc voltage of 0.2 V, (b) difference from the nominal of the voltage measured using the K3458A versus dc bias current for different RF power biases.Figure 4. PD JJA voltage difference from nominal, measured with a K3458A, versus dc bias current for different pulse patterns and repetition frequencies.Figure 5. (a) Current-voltage characteristic of the CWD JJA and (b) the RF power-voltage characteristic of the PD JJA. The error bars show the Type-A uncertainty (k=1) of the measurement of five measurements.Figure 6. Current-voltage characteristic of the CWD JJAs. The error bars show the Type-A uncertainty (k=1) of the measurement.Figure 7. Allan deviation for 0 V. See text for details.Figure 8. Current-voltage characteristic of the CWD JJAs. The error bars show the Type-A uncertainty (k=1) of the measurement.Figure 9. Allan deviation at 1 V.

Resources

Name Format Description Link
Readme file describing the data Text This file describes the associated files and their data contained within the csv and jpg plots for the associated paper. Open resource
Fig 3a Pattern of pulses used to generate a dc voltage of 0.2 V.cvs CSV Pattern of pulses used to generate a dc voltage of 0.2 V.cvs Open resource
Fig. 3b. Difference of the voltage measured using the K3458A from the nominal versus dc bias current for difference RF power bias CSV Fig. 3b. Difference of the voltage measured using the K3458A from the nominal versus dc bias current for difference RF power bias. The error bars show the Type-A uncertainty (k=1) of the measurement. Open resource
Fig. 4. PD-JJA voltage difference from nominal CSV PD-JJA voltage difference from nominal, measured with a K3458A, versus dc bias current for different pulse patterns and repetition frequencies Open resource
Fig 5a Current-voltage characteristic of the CW-JJA CSV Current-voltage characteristic of the CW-JJA Open resource
#Fig 5b the RF power-voltage characteristic of the PD-JJA CSV #Fig. 5. (b) the RF power-voltage characteristic of the PD-JJA. The errors bars show the Type-A uncertainty (k=1) of the measurement of five measurements Open resource
Fig 6 Current-voltage characteristic of the CW-JJAs CSV Current-voltage characteristic of the CW-JJAs. The error bars show the Type-A uncertainty (k=1) of the measurement.csv Open resource
Fig 7 Allan deviation for 0 V. See text for details CSV Fig. 7. Allan deviation for 0 V. See text for details. The straight lines show the weighted least squares fit to a straight line for the data points up to the knee of the curves Open resource
Fig 8 Current voltage characteristic of the CW-JJAs CSV Fig 8 Current voltage characteristic of the CW-JJAs. The errors bars show the Type A uncertainty (k=1) of the measurement.csv Open resource
Fig. 9 Allan deviation at 1V CSV Fig. 9 Allan deviation at 1V Open resource
Fig 3a JPG Pattern of pulses used to generate a dc voltage of 0.2 V Open resource
Fig 3b JPG difference from the nominal of the voltage measured using the K3458A versus dc bias current for different RF power biases. The error bars show the Type-A uncertainty (k=1) of the measurement. Open resource
Figure 4. JPG PD JJA voltage difference from nominal, measured with a K3458A, versus dc bias current for different pulse patterns and repetition frequencies. Open resource
Figure 5 (a) JPG Current-voltage characteristic of the CWD JJA and Open resource
Frig 5b JPG the RF power-voltage characteristic of the PD JJA. The error bars show the Type-A uncertainty (k=1) of the measurement of five measurements. Open resource
Fig 6 JPG Figure 6. Current-voltage characteristic of the CWD JJAs. The error bars show the Type-A uncertainty (k=1) of the measurement. Open resource
Fig 7 JPG Figure 7. Allan deviation for 0 V. See text for details. Open resource
Fig 8 JPG Figure 8. Current-voltage characteristic of the CWD JJAs. The error bars show the Type-A uncertainty (k=1) of the measurement. Open resource
Figure 9 JPG Allan deviation at 1 V. Open resource

Tags

Topics

Categories