Description
IBACOS completed an initial analysis of moisture damage potential in an unvented attic insulated with closed-cell spray polyurethane foam. To complete this analysis, the research team collected field data, used computational fluid dynamics to quantify the airflow rates through individual airflow (crack) paths, simulated hourly flow rates through the leakage paths with CONTAM software, correlated the CONTAM flow rates with indoor humidity ratios from Building Energy Optimization software, and used "Warme und Feuchte instationar Pro two-dimensional modeling" to determine the moisture content of the building materials surrounding the cracks.
Given the number of simplifying assumptions and numerical models associated with this analysis, the results indicate that localized damage due to high moisture content of the roof sheathing is possible under very low airflow rates. Reducing the number of assumptions and approximations through field studies and laboratory experiments would be valuable to understand the real-world moisture damage potential in unvented attics.
Resources
| Name | Format | Description | Link |
|---|---|---|---|
| TO4 7.1.3.beopt | Unknown | Version 2.0.0.6 Temperature and humidity for 3 cities and 3 ACH50 values. | Open resource |
| TO4 7.1.3_BEopt_HoulryOutput.xlsx | XLS | From BEopt Version 2.0.0.6. Hourly temperature and relative humidity output for three different cities, and three different ACH50 values for each city. | Open resource |
| TO4 7.1.3_BEopt_HPXML_10ach50.xml | XML | BEopt Version 2.0.0.6. HPXML for 10ACH50 run | Open resource |
| TO4 7.1.3_BEopt_HPXML_1ach50.xml | XML | BEopt Version 2.0.0.6. HPXML for 1ACH50 run | Open resource |
| TO4 7.1.3_BEopt_HPXML_5ach50.xml | XML | BEopt Version 2.0.0.6. HPXML for 5ACH50 run | Open resource |
| Moisture Risk in Unvented Attics Due to Air Leakage Paths | DOE Report | Open resource |