This is all of the monitoring data collected from the lab house. The fields follow BAFDR dictionary convention. |
https://data.openei.org/files/5492/to4-2.1.2monitoringdata.csv |
|
33 |
In this study, researchers with the U.S. Department of Energy's Building America team IBACOS built on research previously done in two new-construction unoccupied test houses—one in Pittsburgh, Pennsylvania (Poerschke and Stecher 2014) and one in Fresno, California (Stecher and Poerschke 2013). Specific traditional central air distribution systems were installed in each of these low-load homes. For this study, the cold-climate new-construction unoccupied test house in Pittsburgh, Pennsylvania, was modified to test the performance of a heating, ventilating, and air-conditioning (HVAC) system with varied airflow and small-diameter ducts. |
https://www1.eere.energy.gov/buildings/publications/pdfs/building_america/64161.pdf |
|
0 |
BEopt Version 2.0.0.4.
The Pittsburgh lab house (the design labeled "My Design") was run as a Design analysis against the Building America benchmark (the design labeled "Reference"). |
https://data.openei.org/files/5492/to4-2.1.2beopt.beopt |
|
55 |
This is the HPXML file from the attached BEopt file. It is for the Pittsburgh lab home design, labeled "My Design."
|
https://data.openei.org/files/5492/to4-2.1.2hpxml.xml |
|
33 |
Current engineering guidelines for forced-air space-conditioning systems use methodologies that were developed more than 50 years ago and based on the concept that buildings are dominated by externally driven shell loads. Significant advances in thermal enclosure performance suggest that traditional space conditioning systems should be rethought to better handle loads that are more strongly influenced by internal gains.
In a new unoccupied test house in Pittsburgh, Pennsylvania, the U.S. Department of Energy’s Building America team IBACOS assessed the performance of a commercial high-velocity small-diameter air distribution system. The purpose was to test how the system handled the room-to-room cooling and heating loads with respect to Air Conditioning Contractors of America (ACCA) Manual RS criteria for thermal uniformity and ASHRAE Standard 55-2010 criteria for temperature variation with time. The main goal for using the small-diameter (2-in.) duct system was to simplify the installation of ductwork inside conditioned space. |
https://www1.eere.energy.gov/buildings/publications/pdfs/building_america/64162.pdf |