Ionic Fluids for EGS: Fracture Conductivity Tests in Granite Core Samples

Description

This dataset contains experimental measurements of fluid flow and pressure behavior during fracture conductivity tests in granite core samples. The tests were designed to evaluate various ionic and nonionic fluids, including BMiMBr, HPyBF4, HPyBr, an oil-based fluid (OBF-1), and a water-based fluid (WBF-2), under different temperature and pressure conditions relevant to geothermal systems. Data were collected at injection pressures ranging from 500 to 800 psi and temperatures from room temperature up to 80 C. Each file includes multiple sheets organized by fluid type and temperature, containing time-series measurements of pump pressures, flow rates, and volumes for confining, water injection, and intermediate fluid circuits.

Resources

Name Format Description Link
47 This README provides an overview of the dataset, including signal definitions, file naming conventions, test conditions by fluid type and temperature, and a description of the contents and structure of each data file. https://gdr.openei.org/files/1771/README2.txt
53 Fracture conductivity test data for BMiMBr at room temperature and injection pressures of 600, 700, and 800 psi. https://gdr.openei.org/files/1771/MastersBMiMBr_20Degs.xlsx
53 BMiMBr flow data at 50 C with tests conducted at 600, 700, and 800 psi. https://gdr.openei.org/files/1771/MastersBMiMBr_50Degs.xlsx
53 HPyBF4 test results at 50 C with pressure stages of 600, 700, and 800 psi. https://gdr.openei.org/files/1771/MastersHPyBF4_50Degs.xlsx
53 Flow and pressure data for HPyBF4 at room temperature across 600, 700, and 800 psi. https://gdr.openei.org/files/1771/MastersHPyBF4_20Degs.xlsx
53 Fracture flow data for OBF-1 at room temperature and 800 psi, including a summary of test cycles. https://gdr.openei.org/files/1771/MastersOBF1_20Degs.xlsx
53 HPyBr flow testing at 50 C and injection pressures of 600, 700, and 800 psi. https://gdr.openei.org/files/1771/MastersHPyBr_50Degs.xlsx
53 OBF-1 test data collected at 80 C across 600, 700, and 800 psi with final result summaries. https://gdr.openei.org/files/1771/MastersOBF1_80Degs.xlsx
53 IL fluid test data https://gdr.openei.org/files/1771/MastersHPyBr_20Degs.xlsx
53 OBF-1 test results at 50 C with pressures of 700 and 800 psi, including summary sheets. https://gdr.openei.org/files/1771/MastersOBF1_50Degs.xlsx
53 WBF-2 flow tests at room temperature and pressures of 500 to 800 psi, with data grouped into repeated cycles. https://gdr.openei.org/files/1771/MastersWBF2_20Degs.xlsx
53 BF-2 results at 50 C and pressures from 500 to 800 psi, organized across three test cycles. https://gdr.openei.org/files/1771/MastersWBF2_50Degs.xlsx
53 Flow and pressure data for WBF-2 at 80 C with multiple cycles conducted at 500 to 800 psi. https://gdr.openei.org/files/1771/MastersWBF2_80Degs.xlsx

Tags

  • injection-pressure
  • fractured-granite
  • egs
  • core-flooding
  • laboratory-data
  • geothermal-fluids
  • enhanced-geothermal-systems
  • granite-core-tests
  • geochemistry
  • ionic-based-fluids
  • fracture-conductivity
  • ionic-fluids-for-egs
  • flow-rate
  • temperature-dependent-behavior
  • raw-data

Topics