Geothermal Electricity Technology Evaluation Model (GETEM) Individual Case Files and Summary Spreadsheet (GETEM version Spring 2013)

Description

This group of files includes 10 GETEM individual scenario files and 1 summary spreadsheet. Each spreadsheet contains final data (following the revisions made between summer of 2011 and spring of 2013).

Resources

Name Format Description Link
53 GETEM Summary Spreadsheet detailing the results for each of the scenarios. https://gdr.openei.org/files/225/GETEM_Summary_Sheet_March_2013.xlsx
53 GETEM Scenario EGS C using a resource temperature of 175 degrees C and a resource depth of 3000 m with a binary conversion system https://gdr.openei.org/files/225/EGS_C_March%202013%20GETEM_3-7-13.xlsm
53 GETEM Scenario EGS A using a resource temperature of 100 degrees C and a resource depth of 2000 m with a binary conversion system https://gdr.openei.org/files/225/EGS_A_March%202013%20GETEM_3-7-13.xlsm
53 GETEM Scenario EGS D using a resource temperature of 250 degrees C and a resource depth of 3500 m with a flash steam conversion system https://gdr.openei.org/files/225/EGS_D_March%202013%20GETEM_3-7-13.xlsm
53 GETEM Scenario Hydro C using a resource temperature of 175 degrees C and a resource depth of 1500 m with a binary conversion system https://gdr.openei.org/files/225/Hydro_C_March%202013%20GETEM_3-7-13.xlsm
53 GETEM Scenario Hydro B using a resource temperature of 175 degrees C and a resource depth of 1500 m with a flash steam conversion system https://gdr.openei.org/files/225/Hydro_B_March%202013%20GETEM_3-7-13.xlsm
53 GETEM Scenario Hydro A using a resource temperature of 140 degrees C and a resource depth of 1500 m with a binary conversion system https://gdr.openei.org/files/225/Hydro_A_March%202013%20GETEM_3-7-13.xlsm
53 GETEM Scenario EGS B using a resource temperature of 150 degrees C and a resource depth of 2500 m with a binary conversion system https://gdr.openei.org/files/225/EGS_B_March%202013%20GETEM_3-7-13.xlsm
53 GETEM Scenario Hydro D using a resource temperature of 225 degrees C and a resource depth of 2500 m with a flash steam conversion system https://gdr.openei.org/files/225/Hydro_D_March%202013%20GETEM_3-7-13.xlsm
53 GETEM Scenario EGS E using a resource temperature of 325 degrees C and a resource depth of 4000 m with a flash steam conversion system https://gdr.openei.org/files/225/EGS_E_March%202013%20GETEM_3-7-13.xlsm
53 GETEM Scenario Hydro E using a resource temperature of 140 degrees C and a resource depth of 2500 m with a binary conversion system https://gdr.openei.org/files/225/Hydro_E_March%202013%20GETEM_3-7-13.xlsm