| Name |
Format |
Description |
Link |
|
10 |
This document lists the uploaded data file names, explanations for each column of the data tables, and schematic diagrams for the experimental setup and the sensor locations. |
https://gdr.openei.org/files/1362/DCIF_Task3-0_BoroleDamageTest_Westerly_Metadata.docx |
|
9 |
Acoustic emission location data for block H. Block H sample used a pre-test heating temperature of 400 C. See the attached meta file for the explanation of the contents |
https://gdr.openei.org/files/1362/DCIF_Task3-0_location_blockH.dat |
|
47 |
Thermocouple temperature measurement data for block G. Block G sample used a pre-test heating temperature of 600 C. See the attached meta file for the explanation of the contents |
https://gdr.openei.org/files/1362/DCIF_Task3-0_blockG_Thermocouple.TXT |
|
0 |
This animation shows locations of the AE (acoustic emission) events produced within a sample block G, during the local cooling experiment. |
https://gdr.openei.org/files/1362/DCIF_Task3-0_Westerly_blockG_AEmovie.avi |
|
0 |
This animation shows locations of the AE (acoustic emission) events produced within a sample block H, during the local cooling experiment. |
https://gdr.openei.org/files/1362/DCIF_Task3-0_Westerly_blockH_AEmovie.avi |
|
48 |
Graphical presentation of the identified AE onset temperature as a function of the pre-test heating temperature which induced microcrack damage in the sample |
https://gdr.openei.org/files/1362/DCIF_Task3-0_PreCrackingTvsOnsetCuCupTemp.TIF |
|
9 |
Acoustic emission location data for block G. Block G sample used a pre-test heating temperature of 600 C. See the attached meta file for additional explanation of the contents. |
https://gdr.openei.org/files/1362/DCIF_Task3-0_location_blockG.dat |
|
9 |
Acoustic emission location data for block I. Block I sample used a pre-test heating temperature of 200 C. See the attached meta file for additional explanation of the contents. |
https://gdr.openei.org/files/1362/DCIF_Task3-0_location_blockI.dat |
|
48 |
Graphical presentation of the measured average P-wave velocities in the samples as a function of the applied biaxial stress. Different curves are for samples with different pre-heating temperatures which were used to induce a range of microcrack damage |
https://gdr.openei.org/files/1362/DCIF_Task3-0_BiaxialStressVsVelocityAllDamagedSamplesAveVelocity.TIF |
|
0 |
This animation shows locations of the AE (acoustic emission) events produced within a sample block I, during the local cooling experiment. |
https://gdr.openei.org/files/1362/DCIF_Task3-0_Westerly_blockI_AEmovie.avi |
|
47 |
Thermocouple temperature measurement data for block H. Block H sample used a pre-test heating temperature of 400 C. See the attached meta file for the explanation of the contents |
https://gdr.openei.org/files/1362/DCIF_Task3-0_blockH_Thermocouple.txt |
|
48 |
Graphical presentation of the time vs AE rate and cumulative AE counts |
https://gdr.openei.org/files/1362/DCIF_Task3-0_Time%20vs%20AE%20rate%20and%20Cumulative%20Count%20summary.tif |
|
47 |
Thermocouple temperature measurement data for block I. Block I sample used a pre-test heating temperature of 200 C. See the attached meta file for the explanation of the contents |
https://gdr.openei.org/files/1362/DCIF_Task3-0_blockI_Thermocouple.txt |