Current Energy Harnessing using Synergistic Kinematics of Schools of Fish-Shaped Bodies: Marine Hydrodynamics Laboratory Tank Testing Data

Description

The objectives of the proposed work pertain to building a high power-density and high efficiency device to harness MHK energy by mimicking fish-school kinematics. Vortex Hydro Energy is collaborating with a concept formed and undergone preliminary testing at the University of Michigan to complete this task. This submission contains data from the Marine Hydrodynamics Laboratory tank testing for 1, 2, and 3 cylinders. Tests were run in a 10,000 gallon recirculating tank. Cylinders have a diameter of 0.0889 m and 0.895m long. See "Read Me" for file format explanation and additional details.

Resources

Name Format Description Link
47 This contains the table to convert the flow speed in the file names to meters per second. https://mhkdr.openei.org/files/209/FlowSpeedConverter%20%281%29.txt
47 Information relating to the submitted data https://mhkdr.openei.org/files/209/ReadMe.txt
53 Summary of the one cylinder mass ratio 1.007 tests. This file is included in the zip as well. https://mhkdr.openei.org/files/209/OneCylinder_MassRatio1.007_Summary.xlsx
53 Summary of the data collected for the one cylinder mass ratio 1.343 tests. This file is included in the zip as well. https://mhkdr.openei.org/files/209/OneCylinder_MassRatio1.343_Summary.xlsx
53 Summary of data from two cylinder testing Spacing 2.0 cylinder diameters Mass ratio 1.34 This is included in the zip file as well. https://mhkdr.openei.org/files/209/TwoCylinder_Spacing2.0_MassRatio1.34_Summary.xlsx
53 A summary of the data from the two cylinder tests Mass Ratio: 1.343 Spacing: 2.57 Diameters This is in the zip file as well. https://mhkdr.openei.org/files/209/TwoCylidner_Spacing2.57_MassRatio1.34_Summary.xlsx
53 Three cylinder test summary Mass ratio: 1.343 Spacing: 2.01 diameters This is in the zip file as well https://mhkdr.openei.org/files/209/ThreeCylinder_Spacing2.01_MassRatio1.343_Summary.xlsx
53 Summary of three cylinder testing Mass ratio: 1.343 Spacing: 2.01 diameters This is in the zip file https://mhkdr.openei.org/files/209/ThreeCylinder_Spacing2.57_MassRatio1.343_Summary%20%283%29.xlsx
57 Test data of one cylinder mass ratio 1.007 The file names are as follows: The first 8 digits are the date YYYYMMDD The second 6 digits are the time HHMMSS The next number is the spring constant in N/m. e.g. k400 = 400 n/m The next digits are the damping ratio The final digits are the flow speed. Flow speed is expressed in motor frequency. Use FlowSpeedConverter.txt to convert flow speed to m/s. https://mhkdr.openei.org/files/209/OneCylinder_MassRatio1.007.zip
57 Test data of one cylinder mass ratio 1.685 The file names are as follows: The first 8 digits are the date YYYYMMDD The second 6 digits are the time HHMMSS The next number is the spring constant in N/m. e.g. k400 = 400 n/m The next digits are the damping ratio The final digits are the flow speed. Flow speed is expressed in motor frequency. Use FlowSpeedConverter.txt to convert flow speed to m/s. https://mhkdr.openei.org/files/209/OneCylinder_MassRatio1.685.zip
57 Test data of two cylinders, mass ratio 1.343 Spacing 2.0 diameters The file names are as follows: The first 8 digits are the date YYYYMMDD The second 6 digits are the time HHMMSS The next number is the spring constant in N/m with the cylinder number expressed after. e.g. k400_2 = 400 n/m second cylinder The next digits are the damping ratio The final digits are the flow speed. Flow speed is expressed in motor frequency. Use FlowSpeedConverter.txt to convert flow speed to m/s. The data from each cyilnder is stored in a separate file. The timestamp of the cylinders from the same test will match. https://mhkdr.openei.org/files/209/TwoCylinders_MassRatio1.343_Spacing2.0%20%282%29.zip
57 Test data of three cylinders, mass ratio 1.343 Spacing 2.01 diameters The file names are as follows: The first 8 digits are the date YYYYMMDD The second 6 digits are the time HHMMSS The next number is the spring constant in N/m with the cylinder number expressed after. e.g. k400_2 = 400 n/m second cylinder The next digits are the damping ratio The final digits are the flow speed. Flow speed is expressed in motor frequency. Use FlowSpeedConverter.txt to convert flow speed to m/s. The data from each cyilnder is stored in a separate file. The timestamp of the cylinders from the same test will match. https://mhkdr.openei.org/files/209/ThreeCylinders_MassRatio1.343_Spacing2.57.zip
57 Test data of three cylinders, mass ratio 1.343 Spacing 2.01 diameters The file names are as follows: The first 8 digits are the date YYYYMMDD The second 6 digits are the time HHMMSS The next number is the spring constant in N/m with the cylinder number expressed after. e.g. k400_2 = 400 n/m second cylinder The next digits are the damping ratio The final digits are the flow speed. Flow speed is expressed in motor frequency. Use FlowSpeedConverter.txt to convert flow speed to m/s. The data from each cyilnder is stored in a separate file. The timestamp of the cylinders from the same test will match. https://mhkdr.openei.org/files/209/ThreeCylinders_MassRatio1.343_Spacing4.01.zip
53 A summary of the one cylinder mass ratio1.685 tests. This file is included in the zip as well. https://mhkdr.openei.org/files/209/OneCylinder_MassRatio1.685_Summary.xlsx
53 Summary of the three cylinder data Mass ratio: 1.343 Spacing: 4.01 diameters This is in the zip file as well https://mhkdr.openei.org/files/209/ThreeCylinder_Spacing4.01_MassRatio1.343_Summary.xlsx
57 Test data of two cylinders, mass ratio 1.343 Spacing 2.57 diameters The file names are as follows: The first 8 digits are the date YYYYMMDD The second 6 digits are the time HHMMSS The next number is the spring constant in N/m with the cylinder number expressed after. e.g. k400_2 = 400 n/m second cylinder The next digits are the damping ratio The final digits are the flow speed. Flow speed is expressed in motor frequency. Use FlowSpeedConverter.txt to convert flow speed to m/s. The data from each cyilnder is stored in a separate file. The timestamp of the cylinders from the same test will match. https://mhkdr.openei.org/files/209/TwoCylinders_MassRatio1.343_Spacing2.57%20%282%29.zip
53 Summary of the two cylinder data Mass ratio of 1.343 Spacing of 1.57 diameters This file is in the zip file as well. https://mhkdr.openei.org/files/209/TwoCylinder_Spacking1.57_MassRatio1.34_Summary.xlsx
57 Test data of one cylinder mass ratio 1.343 The file names are as follows: The first 8 digits are the date YYYYMMDD The second 6 digits are the time HHMMSS The next number is the spring constant in N/m. e.g. k400 = 400 n/m The next digits are the damping ratio The final digits are the flow speed. Flow speed is expressed in motor frequency. Use FlowSpeedConverter.txt to convert flow speed to m/s. https://mhkdr.openei.org/files/209/OneCylinder_MassRatio1.343.zip
57 Test data of two cylinders, mass ratio 1.343 Spacing 1.57 diameters The file names are as follows: The first 8 digits are the date YYYYMMDD The second 6 digits are the time HHMMSS The next number is the spring constant in N/m with the cylinder number expressed after. e.g. k400_2 = 400 n/m second cylinder The next digits are the damping ratio The final digits are the flow speed. Flow speed is expressed in motor frequency. Use FlowSpeedConverter.txt to convert flow speed to m/s. The data from each cyilnder is stored in a separate file. The timestamp of the cylinders from the same test will match. https://mhkdr.openei.org/files/209/TwoCylinders_MassRatio1.343_Spacing1.57%20%282%29.zip
57 Test data of three cylinders, mass ratio 1.343 Spacing 2.01 diameters The file names are as follows: The first 8 digits are the date YYYYMMDD The second 6 digits are the time HHMMSS The next number is the spring constant in N/m with the cylinder number expressed after. e.g. k400_2 = 400 n/m second cylinder The next digits are the damping ratio The final digits are the flow speed. Flow speed is expressed in motor frequency. Use FlowSpeedConverter.txt to convert flow speed to m/s. The data from each cyilnder is stored in a separate file. The timestamp of the cylinders from the same test will match. https://mhkdr.openei.org/files/209/ThreeCylinders_MassRatio1.343_Spacing2.01%20%281%29.zip

Tags

  • oscillating
  • cec
  • viv
  • transformative
  • mass-ratio
  • converter
  • vortex-induced-vibrations
  • hydrokinetic
  • meters-per-second
  • mhk
  • river
  • cylinder-data
  • oscylator-4
  • fish-mhk
  • 3-d-converter
  • michigan
  • fish
  • testing
  • marine
  • lab-data
  • ann-arbor
  • lab-test
  • ocean
  • tank-test
  • power
  • school
  • current
  • flow-speed
  • oscylator
  • shaped
  • fish-vivace
  • synergistic-kinematics
  • technology
  • vivace
  • current-energy
  • body
  • vortex-hydro-energy
  • energy

Topics

Categories