Continuous water quality sensor data from the main channel and a backwater of the Upper Mississippi River from 2015-2018

Description

This dataset includes high-frequency sensor data collected during four consecutive summers from buoys deployed at main channel and backwater sites in Pool 8 of the Upper Mississippi River from 2015-2018. It also includes the event-specific concentration-discharge metrics (hysteresis and slope) calculated by combining the water quality sensor data with discharge data from a nearby USGS gage in Winona, MN (05378500). High-frequency sensor data were collected using water quality buoys (PISCES monitoring platforms; EMM350 Water Monitoring Pontoon Platform | ysi.com | ysi.com; Yellow Springs, Ohio) set up with EXO2 Multiparameter Sondes (YSI, Inc, Yellow Springs, Ohio) to monitor hourly or bi-hourly concentrations of chlorophyll-a, phycocyanin (metric of cyanobacteria abundance),, fluorescent dissolved organic matter (FDOM; QSU), and turbidity (FNU), and water temperature (Celsius) as well as a SUNA v2 nitrate sensor (Sea-Bird Scientific, Bellevue, Washington) to monitor nitrate concentration.

Resources

Name Format Description Link
55 The metadata original format https://data.usgs.gov/datacatalog/metadata/USGS.642dc2bcd34ee8d4add3b0b1.xml
55 Landing page for access to the data https://doi.org/10.5066/P9FGYHVS

Tags

  • mississippi-river
  • chlorophyll-a
  • usgs-642dc2bcd34ee8d4add3b0b1
  • dissolved-organic-matter
  • phycocyanin
  • nitrogen
  • water-quality
  • inlandwaters
  • biogeochemistry
  • turbidity

Topics