Daily parameter-dependent load profile heat pump from 2013 (Berlin)
Description
Daily parameter-dependent load profiles (TLP) for interruptible load profiles
Consumables.
The network operator has defined the Berlin Dahlem weather station (WMO 10381) as the decisive temperature measuring point for the average day temperature.
For the selection of the TLP for interruptible consumables, the
Temperature measurement number (TMZ) to be used: TMZ = Max (Treference — Tm,ä; K)
The equvalent daily average temperature (Tm,ä) is derived from:
TM,ä = 0.5 * Tm(d) + 0.3 * Tm(d-1) + 0.15 * Tm(d-2) + 0.05*Tm(d-3)
The average daily temperature (Tm) is the average of the air temperature of the past 24 hours, formed from the half-hour temperature values from 00:30 a.m. to 2:00 p.m.
The reference temperature TBezug is set for all TLP + 17 °C. Above this
Temperature is to select the load profile for + 17 °C.
The design temperature (lowest temperature) is defined for all TLP -15 °C.
Below this temperature, select the load profile for -15 °C.
Resources
| Name |
Format |
Description |
Link |
|
53 |
|
https://www.stromnetz.berlin/globalassets/dokumente/netz-nutzen/standardlastprofile/tagesparameterabhangige/tlp-waermepumpe-b-ab-2013_22500816.xls |